- Sensors[10]
- Relays[10]
- Timers[1]
- Switching Power Supply[4]
- AC/DC Adapters[7]
- Temperature Instruments[9]
- HVAC Systems & Parts[3]
- Capacitors[5]
- Other Electrical Equipment[1]
- Current Meters[1]
- Voltage Meters[7]
- Power Meters[1]
- Energy Meters[1]
- Power Distribution Equipment[3]
- Electronic & Instrument Enclosures[10]
- Contactors[10]
- Circuit Breakers[9]
- Fuses[2]
- Arc Welders[1]
- Uninterrupted Power Supply (UPS)[6]
- Voltage Regulators/Stabilizers[4]
- Pliers[2]
- Other Hand Tools[3]
- Terminal Blocks[2]
- Insulation Materials & Elements[4]
- Inverters & Converters[7]
- AC Motor[2]
- Filters[3]
- Wall Switches[10]
- Street Lights[1]
- Other Lights & Lighting Products[10]
- Electrical Plugs & Sockets[10]
- Push Button Switches[10]
- Other Switches[1]
- Solar Cells[8]
- Transformers[7]
- Other Interior Accessories[5]
- Auto Lighting System[4]
- Other Auto Electronics[2]
- Multimeters[1]
- Contact Person : Mr. Wong Kobe
- Company Name : Yueqing Winston Electric Co., Ltd.
- Tel : 0086-577-27852809
- Fax : 0086-577-27875159
- Address : Zhejiang,Wenzhou,Changhong Industrial Zone,Liushi Town,Yueqing
- Country/Region : China
- Zip : 325604
DP-816 Split Core CT
DP-816 Split Core CT
Description The DP Series current transformer has been specially designed to failitate their installation in new or already existing net works. They may be installed without opening any cable or bus-bar iruit. The connection of conventional CTs usually requires the interruption of the primary side circuit to pass cables or bus-bars through the transformer core or to connect such cables to the primary terminals. The DBP Series transformers core may be easily opened and they may be installed and connected without any suply interruption. Thus saveing time and the installation costs Feature -Two built in fixing methods: base; busbar mounting -Very easy to mounting. -Wide inner window, allowing clamping of big cables or bus-bar. -wide range of sizes to accommodate all the existing installations. -primary current from 5A to 5000A Specificaions Rated Frequency :50/60 Hz Rated Test Voltage: 3KV AC.(1min) Rated short-time thermal current(Ith): 60In Rated dynamic current(Idyn): 2.5Ith Rated Voltage(Um): 0.72KV AC Continuous overload(Id): 1.2In Ambient Temperature:-10oC to +50oC Housing self-extinguishing class: VO Safety factor: FS 5 Secodary current: 5A/1A *Other tecnical specification. on request Standard IEC60044-1, EN60044-1, VDE0414-44-1, GB1208-2006
Type | Ration (A) | Burden (VA) | |
Class: 0.5 | Class:1.0 | ||
DP-23 | 200/5 | - | 1.5 |
250/5 | - | 2.5 | |
300/5 | 1.5 | 2.5 | |
400/5 | 2.5 | 3.75 | |
DP-58 | 250/5 | - | 1.5 |
300/5 | - | 2.5 | |
400/5 | 1.5 | 2.5 | |
500/5 | 2.5 | 5 | |
600/5 | 2.5 | 5 | |
750/5 | 2.5 | 5 | |
800/5 | 3.75 | 5 | |
1000/5 | 5 | 10 | |
DBP-88 | 250/5 | - | 1.5 |
300/5 | - | 1.5 | |
400/5 | - | 2.5 | |
500/5 | 1.5 | 2.5 | |
600/5 | 2.5 | 5 | |
750/5 | 2.5 | 5 | |
800/5 | 3.75 | 5 | |
1000/5 | 5 | 10 | |
DP-812 | 500/5 | - | 2.5 |
600/5 | - | 2.5 | |
750/5 | 2.5 | 5 | |
800/5 | 2.5 | 5 | |
1000/5 | 3.75 | 7.5 | |
1200/5 | 5 | 10 | |
1250/5 | 5 | 10 | |
1500/5 | 7.5 | 10 | |
DP-816 | 1000/5 | 5 | 10 |
1500/5 | 7.5 | 10 | |
2000/5 | 10 | 15 | |
2500/5 | 15 | 20 | |
3000/5 | 20 | 25 | |
4000/5 | 20 | 25 | |
5000/5 | 20 | 25 |
DP-816 Split Core CT